CKGMC - TRIS-HCI 1M PH 7.5, 351-006-130
- MSDS: CKGMC
- Manufacturer: QUALITY BIOLOGICAL INC
- Product Name: TRIS-HCI 1M PH 7.5, 351-006-130
- National Stock Number: -
Product Identification
Product ID:TRIS-HCI 1M PH 7.5, 351-006-130
MSDS Date:05/25/1999
FSC:NIIN:Submitter:N EN
Status Code:A
MSDS Number: CKGMC
Responsible Party
GAITHERSBURG, MD 20879
US
Emergency Phone: 800-443-9331
Info Phone: 301-840-9331
Cage: 0PXC7
Contractor
Telephone: 301-840-9331
Cage: 0PXC7
Ingredients
1,3-PROPANEDIOL, 2-AMINO-2-(HYDROXYMETHYL)-; (TRIS BASE)
CAS: 77-86-1
RTECS: TY2900000
OSHA PEL N/K
ACGIH TLV: N/K
HYDROCHLORIC ACID
CAS: 7647-01-0
RTECS: MW4025000
OSHA PEL C7 MG/M3;C5 PPM
ACGIH TLV: N/K
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
WATER
CAS: 7732-18-5
RTECS: ZC0110000
OSHA PEL N/K
ACGIH TLV: N/K
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:THE TOXICOLOGICAL PROPERTIES OF THIS
PRODUCT HAVE NOT BEEN DETERMINED. THE SOLUTION MAY CAUSE ACUTE OR
CHRONIC IRRITATION OF SKIN, EYES AND MUCOUS MEMBRANES.
Effects of Overexposure:SEE HEALTH HAZARDS.
First Aid
First Aid:INGESTION: REPEATEDLY RINSE MOUTH WITH WATER. DRINK LARGE
QUANTITIES OF WATER. GET MEDICAL ATTENTION IF IRRITATION PERSISTS.
SKIN: IMMEDIATELY WASH SKIN WITH SOAP AND FLUSH WITH LARGE AMOUNTS
OF WATER FOR AT LEAST 15 MINUTES. GET MEDICAL ATTENTION IF CONTACT
AREA REMAINS IRRITATED. EYES: IMMEDIATELY FLUSH EYES WITH LARGE
AMOUNTS OF WATER FOR AT LEAST 15 MINUTES. GET MEDICAL ATTENTION IF
EYES REMAI N IRRITATED. INHALATION: REMOVE TO FRESH AIR. SUPPORT
BREATHING (GIVE OXYGEN OR ARTIFICIAL RESPIRATION) . EMERGENCY
EXPOSURE INFORMATION: 1-800-424-8802 (NATIONAL RESPONSE CENTER).
Fire Fighting
Extinguishing Media:USE EXTINGUISHING MEDIA APPROPRIATE TO SURROUNDING
FIRE CONDITIONS.
Fire Fighting Procedures:WEAR NIOSH APPROVED SELF-CONTAINED BREATHING
APPARATUS AND FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:MAY EMIT TOXIC FUMES OF CARBON MONOXIDE,
CARBON DIOXIDE, AND NITROGEN OXIDES UNDER FIRE CONDITIONS.
Accidental Release
Spill Release Procedures:WEAR PROTECTIVE CLOTHING AND SAFETY GLASSES
WHILE CLEANING UP THE SPILL. MINIMIZE SPREAD OF LIQUID USING
APPROPRIATE ABSORBENT MATERIAL. PLACE IN CLOSED CONTAINERS FOR
DISPOSAL.
Handling
Handling and Storage Precautions:STORE IN TIGHTLY CLOSED CONTAINER AT
ROOM TEMPERATURE. MAY CAUSE EYE AND SKIN IRRITATION. DURING USE,
AVOID CONTACT WITH EYES, SKIN AND CLOTHING. WHEN NOT IN USE, KEEP
IN TIGHTLY CLOSED CONTAINER.
Other Precautions:THIS PRODUCT IS FOR RESEARCH USE ONLY. THIS PRODUCT
HAS NOT BEEN APPROVED FOR DIAGNOSTIC OR THERAPEUTIC USE.
Exposure Controls
Respiratory Protection:USE NIOSH APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Protective Gloves:WEAR PROPER GLOVES. WEAR IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:EYEWASH AND DELUGE SHOWER MEETING ANSI
DESIGN CRITERIA . WEAR LAB COAT.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
WEIGHT/VOLUME: TRIS BASE: 121.14 G/L; HYDROCHLORIC ACID: 64.0 G/L;
WATER: NOT APPLICABLE.
Chemical Properties
pH:7.5 +/- 0.1
Appearance and Odor:CLEAR, COLORLESS LIQUID; ODORLESS.
Stability
Stability Indicator/Materials to Avoid:YES
Disposal
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH ALL APPLICABLE
FEDERAL, STATE AND LOCAL ENVIRONMENTAL REGULATIONS.
Toxicology
Toxicological Information:THE TOXICOLOGICAL PROPERTIES OF THIS PRODUCT
HAVE NOT BEEN DETERMINED.
Other Information
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their